Operating Environment Software Owner's manual

NOTE: Do not select the Unmanage Logical Server option. Doing so will cause the logical server
storage pool entry to be modified so as to contain new WWNs without regard to presentation or zoning.
Follow the procedure in “Configuring storage pool entries, FC zones, and disk array presentationsto
resolve this issue.
3. Verify that in Virtual Connect Enterprise Manager the VC profile associated with the failed server blade
exists. If the profile exists, unassign and delete the VC profile associated with the failed server blade
from Virtual Connect Enterprise Manager.
4. Move the server blade out of Insight Orchestration maintenance pool.
a. In the Insight Orchestration console (accessed from Systems Insight Manager), select the original
server blade pool and click Modify.
b. Pull the failed server from the Insight Orchestration Maintenance Pool back to your server blade
pool and then save the pool.
NOTE: In previous versions of Insight software the “Delete Logical Server” option was presented as
the “Delete with Unrecoverable” option and the “Unmanage Logical Server” option was presented as
the “Delete with Recoverable” option.
78 Troubleshooting