Operating Environment Software Owner manual

B Working with Brocade Fibre Channel networks
Minimum requirements
Brocade Network Advisor or HP B-Series Network Advisor must be installed in order to manage
Brocade based SAN environments. SPM supports the following Brocade Network Advisor software
packages:
Brocade Switch FOS/M-EOSc versionSAN Management Software
FOS v5.0.x, v5.1.x, v5.2.x, v5.3.x, v6.0.x. v6.1.x, v6.2.x,
v6.3.x, v6.4.x, v7.0.x; for specific devices, as listed in the
HP B-Series Network Advisor 11.1.3 (Enterprise,
Professional Plus, or SMI Agent Only) options
release notes, M-EOSc 9.6.x, 9.7.x, 9.8.x and 9.9.x are
also supported.
Brocade Network Advisor (BNA) v11.1.3 (Enterprise,
Professional Plus, or SMI Agent Only) options
HP B-Series Network Advisor 11.1.4 (Enterprise,
Professional Plus, or SMI Agent Only) options
Brocade Network Advisor (BNA) v11.1.4 (Enterprise,
Professional Plus, or SMI Agent Only) options
NOTE:
Brocade's legacy standalone SMI Agent is not supported by SPM. SPM will only support the
SMI Agent installed via HP B-Series Network Advisor/Brocade Network Advisor installation
packages as called out above.
For more information and access to HP B-Series Network Adviser software, see HP B-series
Management Software - Overview & Features. Download information can be found under
“HP Support and Drivers.
Configuring SPM to communicate with SANs
When managing Brocade-based SAN environments, SPM must have access to Brocade's network
device manager, which is outlined in the Minimum Requirements section.
IMPORTANT: SNMP registration must be configure properly on all switches BNA is managing
for SPM to recognize endpoints on such switches. Endpoints connected to switches with faulty BNA
SNMP registration will not be recognized by SPM.
Make sure the following requirements have been met.
1. Check that BNA SMI Agent is installed on a server.
2. Check that a BNA administrator account with full access is configured and available for use
by SPM when communicating with BNA.
3. Check that the CIMOM is up and running on the server.
4. Check that SSL is enabled in BNA.
5. Check that the CIMOM is bound to the NIC that is on the same subnet that SPM is on so that
SPM can connect and communicate with Brocade's network device management software.
Importing a network
To import a network, see Importing a network.
Managing networks
For additional information on managing networks, see Managing networks.
For additional information on removing a network, see Removing a network.
Minimum requirements 69