HP Integrity Servers with Microsoft Windows Server 2008 Release Notes v6.2

Express Setup fails when launched from EBSU
Issue The OS installer fails when launched by EBSU if the DVD drive is attached to
a U320 controller.
Servers All Integrity
Workaround Exit EBSU.1.
2. Put the OS media in the DVD drive.
3. From the EFI Shell, issue the reconnect -r command followed by the
map -r command.
4. Run the OS installer.
Fibre Channel
Error message during system boot
Issue On a system with an Emulex LPe1205-HP 8 Gb Mezzanine card, during system
boot, a VOLTAGE_DEGRADES_TO_NON_RECOVERABLE message is posted in
the System Event Log (SEL). You can view this message with the SL command
under the MP menu.
Servers HP Integrity BL860c Server Blade and BL870c Server Blade
Workaround This is only an alert message. The function and performance on the Mezzanine
card are not adversely affected. No actions are needed.
Mixing Fibre Channel HBA models within same system might cause a blue screen
Issue Mixing HBA cards from different vendors with different I/O maximum transfer
packet sizes in a Multipath I/O (MPIO) configuration on the same server can
cause a blue screen with Stopcode 0x000000D1 and a reference to elxstor.sys.
Servers All Integrity
Workaround Do not mix HBAs from different vendors in the same server configuration in
an MPIO environment.
AH400A or the AH401A 8 Gb Fibre Channel HBAs might cause startup problems or blue screen
Issue Installation of the AH400A or the AH401A 8 Gb Fibre Channel HBAs can cause
startup problems or a blue screen with Stopcode 124 or 7B.
Servers Superdome SX2000, rx8640, rx7640, rx6600, rx3600, rx2660
Workaround The type of workaround depends on whether you are using the AH400A or
AH401A as a data controller or a boot controller.
Data Controller
If you are using the AH400A or AH401A as a data controller, follow these steps:
1. Check the Engineering Date Code (EDC) on your controller before installing
into an Integrity server running Windows Server 2008. If it is A-4832 or
newer, go to step 6.
2. Download the ASPM/MSI-X Vector update utility to a USB flash drive from
ftp://ftp.hp.com/pub/servers/software/WindowsIntegrity/. See the latest
version of the Release Notes at http://docs.hp.com for the latest information
about this utility and file name.
3. Install the controller.
4. Boot to the EFI Shell.
Troubleshooting Common Issues 19