HP Integrity Servers with Microsoft Windows Server 2008 Release Notes v6.2

Workaround The controllers start up normally and function properly after rebooting the
system.
Target LUN and boot controller WWN not visible in a VC environment
Issue When installing to storage attached to an Emulex LPe1105 mezzanine controller
(403621-B21) in a Virtual Connect (VC) environment through a Brocade switch,
the target LUN is not visible and the WWN for the boot controller is not visible
in the zone in the switch administrative tool.
Servers HP Integrity BL860c Server Blade and BL870c Server Blade
Workaround Write down and save the controller World-Wide Number (WWN) when
installing it into the system, or obtain it from the VC manager or EFI utility.
Then, manually enter the WWN into the desired zone on the switch when
configuring the zone. Scan for targets and continue with the usual installation
steps to boot from the controller. For more information, see the HP StorageWorks
Booting Windows for Itanium-based systems from a storage area network document
at http://www.hp.com.
HP Smart Update Manager
hpsum_swdiscovery.exe Application Error
Issue
Version 3.4.3.0 of the hpsum_swdiscovery.exe tool can cause an Application
Error that is reported in the Windows Event Log.
Servers All Integrity
Workaround
1. Navigate to the C:\CPQSYSTEM\cpxml folder.
2. Remove the cp009280.xml file.
3. Restart SMH.
If any pop-up windows display that contain the sw_discovery.exe
application name, follow these steps:
1. Navigate to the C:\Program Files\HPWBEM\Tools folder.
2. Replace the hpsum_swdiscovery.exe file with the same file in the
Support Pack that you downloaded.
Installation
Integrity PCI-express power management fix for AH400A/AH401A is always ready to install
Issue The Integrity PCI-express power management fix for the AH400A and AH401A
HBAs (cp009436.exe) is always “ready to install” even after it is installed.
This can occur when running HPSUM interactively from the Smart Setup CD
or after you download the Support Pack from the web and run it interactively.
Servers All Integrity
Workaround There is no workaround. You can ignore this message after you install the
package.
HPSUM does not detect installed version of Neterion 10Gb NIC driver
Issue If the Neterion 10 Gb NIC driver is already installed with the Reinstallation
DVD, and HPSUM is run for the first time, the driver is displayed in the install
required group, instead of already installed one. When the smart component
is executed, it identifies the installed driver is same as the available version and
does not execute the installation.
Servers Superdome SX2000, rx8640, rx7640, rx6600, rx3600, rx2660
Troubleshooting Common Issues 21