User's Manual

The Temperatures page displays the following information:
Sensor—The ID of the temperature sensor, which also gives an indication of the sensor location.
Status—The temperature status.
Current Reading—The temperature recorded by the listed temperature sensor. If a temperature
sensor is not installed, the Current Reading column shows the value N/A.
Thresholds—The temperature thresholds for the warning for overheating conditions. The two
threshold values are Caution and Critical. If a temperature sensor is not installed, the Thresholds
column shows the value N/A.
Temperature Meter—A graphical representation of the current temperature reading and
whether that reading has reached the Caution or Critical thresholds. The left edge of the
column represents a temperature of 0°C, the grey bar represents the Caution threshold, and
the right edge of the column represents the Critical threshold. If a temperature sensor is not
installed, is missing, or is not reporting a temperature reading, an empty graph is displayed.
Viewing and managing active iLO CM firmware sessions
Select Active Sessions in the main menu to view the active iLO CM firmware sessions.
All active sessions are listed in the All Sessions section, and the current session is also listed in the
Current Session section.
36 Using the web interface to view Moonshot System details