5.5 PatchiX Training

Figure 6-7. After forcing the enhancement MPEHX16B
To force the enhancement to qualify, highlight the patch and press the Force[f3] or F key.
Then press the [f4] key to re-qualify the changes since the last patch qualification. The
resulting patch list is shown in above in Figure 6-7.
Patch Requalification
Every time you make some change using the Force, Undo Force, Veto, or Undo Veto
functionality you will need to re-qualify the set of patches. You can save the re-
qualification until you have forced and vetoed several patches or do it right away. To see
what changes in qualification status have occurred you can use the filter functionality of
the Qualify Patches screen. Press the 4 key to see the list filtered by the Filter(4) =
Difference filter. This process filters out all patches except those that changed
qualification status in the last re-qualification.
Patch List Filters
In the Qualify Patches screen you have a number of filters you can select to customize the
list of patches that are displayed. The current filter is displayed in the upper right hand
corner. You can use the[f5][f6] keys to select the previous and next filters respectively, or
access the filters directly using their filter number.