HP RPG/XL Programmer's Guide (30318-90001)

7-: 5
Comments
1 This Header Specification changes the default error handling for
input file sequence errors.
Column 55 contains N to specify that the error message for
sequence errors be suppressed. Instead of the normal response
to sequence errors, take the action entered in column 58.
Column 58 contains 0 to ignore input file sequence errors and to
continue program execution.
TurboIMAGE Errors. If you're using an TurboIMAGE database, you may see
TurboIMAGE errors. To find the explanation and remedies for TurboIMAGE
errors, see the
TurboIMAGE/XL Database Management System manual
.
Figure 7-5 shows what an TurboIMAGE read error message looks like.
Figure 7-5. An TurboIMAGE Error
USWITCH Errors. USWITCH errors may occur when you use the USWITCH Source
feature (column 16 in the Header Specification). Appendix B of the
HP
RPG Reference Manual
contains a complete description of the USWITCH
errors and recovery procedures for them.
These are the USWITCH error messages you may encounter:
I/O ERROR ON $STDLIST
I/O ERROR ON $STDIN
INVALID INPUT DATA
UNEXPECTED END OF FILE
Figure 7-6 shows what a typical USWITCH error display looks like.