Configuring and Managing Host-Based X.25 Links - Edition 5 (36939-90054)

Appendix A 173
Error Messages
DCC Error Messages
Action: Validate the NMCONFIG.PUB.SYS file and restart DTS. If the
error persists, replace the file, validate it, and restart DTS.
DCC ERROR P-L, configuration record data was invalid. NM Path:
NMMGRpath (DCCERR=5)
(DCCERR 5) Cause: Data in the NMCONFIG.PUB.SYS file was not validated or the
data is corrupt.
Action: Validate the NMCONFIG.PUB.SYS file and restart DTS.
DCC ERROR P-L, (HLIO status SSSSSSSS, ldev LLL). (DCCERR=6)
(DCCERR 6) Cause: A problem exists with the high-level I/O services.
Action: Contact your Hewlett-Packard support representative.
DCC ERROR P-L, (Buffer manager status SSSSSSSS). (DCCERR=7)
(DCCERR 7) Cause: A problem exists with the datacomm buffers.
Action: Contact your Hewlett-Packard support representative.
DCC ERROR P-L, (External procedure not found, status SSSSSSSS).
(DCCERR=8)
(DCCERR 8) Cause: A problem exists with DCC execution.
Action: Contact your Hewlett-Packard support representative.
DCC ERROR P-L, (Memory management error status SSSSSSSS).
(DCCERR=9)
(DCCERR 9) Cause: A problem with the system occurred; the DCC cannot obtain
memory.
Action: Contact your Hewlett-Packard support representative.
DCC ERROR P-L, (Ports status SSSSSSSS). (DCCERR=10)
(DCCERR 10) Cause: A problem with the DCC or the port's subsystem occurred.
Action: Contact your Hewlett-Packard support representative.
DCC ERROR P-L, time out on reply msg, descriptors MMM.
(DCCERR=11)
(DCCERR 11) Cause: The DCC did not receive a reply message within the allotted
time.
Action: Contact your Hewlett-Packard support representative.
DCC ERROR P-L, too many DTCs configured. (DCCERR=12)
(DCCERR 12) Cause: The NMCONFIG.PUB.SYS file contains more than the supported
number of DTCs.
Action: Delete the excess DTCs from the NMCONFIG.PUB.SYS file and
restart DTS.