HP System Dictionary/XL SDMAIN Reference Manual (32256-90001)

A-185
1703 MESSAGE Cannot specify ! after a REPORT command (SDERR 1703)
CAUSE The specified command (CONFIGURE or FORMAT) cannot be issued after the
REPORT command has been issued for a stored report.
ACTION Cancel the current report (using [[Control]] Y) if interactive. Then START the report
again issuing the indicated command before the REPORT command. Or, SAVE the
current report and then use the EDIT REPORT command to insert the indicated
command into the report.
1704 MESSAGE A START command is already active (SDERR 1704)
CAUSE A START/SAVE pair is already active so another cannot be initiated.
ACTION Complete the current START/SAVE pair and then another START can be issued.
Remember, [[Control]] Y can be used to cancel the current START/SAVE pair.
1705 MESSAGE No START command has been issued (SDERR 1705)
CAUSE A SAVE cannot be issued here because no START has been issued to initiate the
storage of commands.
ACTION Issue a START command and enter the command to be stored. Then, the SAVE
command will be accepted.
1706 MESSAGE No REPORT command so START is active. <Control-Y> to stop. (SDERR 1706)
CAUSE A REPORT command is required within a START/SAVE pair. As one has not been
issued, the START remains active so one can be entered.
ACTION Enter a REPORT command and then issue the SAVE. Or, use the [[Control]] Y (if
interactive) to cancel the START.
1707 MESSAGE No REPORT command was specified. START is cancelled (SDERR 1707)
CAUSE A REPORT command is required within a START/SAVE pair. As input is NOT
interactive, the START is cancelled so further processing can take place.
ACTION Update the command file to include a REPORT within the START/SAVE.
1708 MESSAGE Cannot create REPORT so START is active. <Control-Y> to stop (SDERR
1708)
CAUSE The indicated report cannot be created. Accordingly, the START remains active so the
problem with the report can be corrected without losing the commands to be saved.
ACTION Refer to the associated error and correct the problem indicated. Then, issue the SAVE
command. Or, issue a [[Control]] Y (if interactive) to cancel the START.
1709 MESSAGE Cannot create REPORT. START is cancelled (SDERR 1709)
CAUSE The indicated report cannot be created. As input is NOT interactive, the START is
cancelled so further processing can take place.
ACTION Refer to the associated error and correct the problem indicated.
1710 MESSAGE Definition too long so REPORT not stored and START cancelled (SDERR
1710)
CAUSE The commands to be stored are too long to store in the dictionary. Because there is no
way to shrink the commands, the START is cancelled.
ACTION Reissue the START and enter the commands again. However, this time use simpler