MPE/iX System Utilities Reference Manual (32650-90908)

UPSUTIL for MPE/iX
UPSUTIL OVERVIEW
Chapter 32
236
The UPSUTIL command set is summarized in the following (Table 32-1) Subsequent sections of this
document explain the commands in detail.
General Command Parser Errors
Since the UPSUTIL user interface for entering commands is very simple, there are only a few error conditions
associated with entering commands.
First, if a command keyword is simply mis-typed (misspelled), then UPSUTIL outputs the error message:
** ERROR: This command is not known to the UPSUTIL program, command ignored.
Second, if a command keyword contains an invalid character, such as a numeric digit or special punctuation
character, then UPSUTIL outputs the error message:
** ERROR: This command name is not legal, command ignored.
Third, if a command keyword is just too long to be valid, then UPSUTIL outputs the error message:
** ERROR: This command name is too long, command ignored.
Table 32-1 UPSUTIL Commands Summary
Command Name Keyword Command Function
Help help Displays the menu of UPSUTIL commands.
Exit exit Terminates UPSUTIL execution, returns to CI.
Show UPS Devices
Configuration
config Queries the running system for UPS devices
configuration information, and displays the list of
configured UPS Ldevs.
Set new UPS Monitor
Configuration
newconfig Commands the UPS Monitor to start using a new,
user-specified configuration file, which establishes
some operating characteristics of the UPS Monitor.
Show UPS Monitor
Status
status Queries the running system for UPS Monitor
process status and UPS devices statuses, and
displays those statuses to the user.
Start UPS Monitor start Starts execution of the systems UPS Monitor
process, if it is not currently running.
Stop UPS Monitor stop tops execution of the systems UPS Monitor process,
if it is currently running.
Restart UPS Monitor restart Restarts (stops, then starts) execution of the
systems UPS Monitor process, if it is currently|
running.
Reset UPS Powerfail
Indicators
resetpfail Resets (clears) the status indicators that show the
completion dates and times of the previous
occurrences of UPS powerfail grace period timer
runout and UPS powerfail user command file
execution.