NS3000/iX Error Messages Reference Manual (36923-90043)

202 Chapter16
100VG-AnyLAN and HP-PB 100Base-T Error Messages
SDI Driver Specific Status Values
1130 CLAS0001 MESSAGE: Adapter card found does not match software
configuration.
CAUSE: During a link-open operation by an upper level subsystem, the
link module configurator found a supported adapter card at the path
specified in NMCONFIG, but it was not the right type of card for the
link being started.
ACTION: Correct the network configuration or plug in the correct type of
adapter card, and retry the operation. The module configurator cleaned
up and returned an error to the subsystem.
1140 CLAS0001 MESSAGE: Cannot create a buffer pool.
CAUSE: During a link-open operation by an upper level subsystem, the
link module configurator encountered an error while trying to create an
outbound buffer pool (“Cause” = 32-bit status from the call to
bmgr_create_pool).
ACTION: The system may be low on available memory. The module
configurator cleaned up and returned an error to the subsystem.
Try stopping some applications or sessions and retry the operation. If
the problem persists, stop all networking and restart it, or restart the
system.
The buffer size and pool size are not configurable. If the problem still
occurs, there could be a problem with the buffer manager. See Appendix
A , “Submitting a CR.
1150 CLAS0001 MESSAGE: Cannot create a buffer pool.
CAUSE: During a link-open operation by an upper level subsystem, the
link module configurator encountered an error while trying to create a
control buffer pool (“Cause” = 32-bit status from the call to
bmgr_create_pool).
ACTION: The system may be low on available memory. The module
configurator cleaned up and returned an error to the subsystem.
Try stopping some applications or sessions and retry the operation. If
the problem persists, stop all networking and restart it.
The buffer size and pool size are not configurable. If the problem still
occurs, there could be a problem with the buffer manager. See Appendix
A , “Submitting a CR.
1160 CLAS0001 MESSAGE: Cannot load driver plabel.
CAUSE: During a link-open operation by an upper level subsystem, the
link module configurator encountered an error while trying to load the
code for the driver (“Cause” = 32-bit status from the call to
io_get_mgr_entry).
ACTION: Probably not all software required to operate this type of link
is installed. The software was incorrectly installed, or you may need to