NS3000/iX Error Messages Reference Manual (36923-90043)

248 Chapter16
100VG-AnyLAN and HP-PB 100Base-T Error Messages
SDI Driver Specific Status Values
6200 CLAS0001 MESSAGE: Driver encountered a hardware problem.
CAUSE: During a HP-PB 100Base-T connect sequence, the driver
attempted to adjust the duplex setting of the LAN controller chip, but
encountered an error trying to read from the network command
register on that chip (“Cause” = 32-bit status from the call to
vg_dio_read8). Most likely a powerfail has occurred.
ACTION: If a power failure has actually occurred, this error can be
ignored; the driver should recover automatically. But if the same
problem happens every time, see Appendix A , “Submitting a CR.
6230 CLAS0001 MESSAGE: Driver encountered a software problem.
CAUSE: During a HP-PB 100Base-T connect sequence, after the link
failed to connect, the driver started a retry, but encountered an error
while trying to stop and release a timer (“Cause” = 32-bit status from
the call to vg_stop_timer). This timer was used to wait for the link to
connect. If this error is reported, it is because the driver has already
encountered some other error.
ACTION: This is a warning that some timer resources may have been
lost. The link did not connect. Typically preceded by another error
message giving better information about the original cause; check log
data for that error and look it up also. Unless this happens constantly,
the system should continue to run, and the driver will probably retry
the connect. If the problem happens every time, see Appendix A ,
“Submitting a CR.
6260 CLAS0001 MESSAGE: Driver encountered a hardware problem.
CAUSE: While a HP-PB 100Base-T link was connected, the driver
received a notification the link may be down, but when it went to check,
it encountered an error trying to read from the generic status register
on the PHY chip (“Cause” = 32-bit status from the call to
vg_mii_read16). Most likely a powerfail has occurred.
ACTION: If a power failure has actually occurred, this error can be
ignored; the driver should recover automatically. Otherwise, the MII
bus may have failed; replace the adapter card. If the same problem
persists, see Appendix A , “Submitting a CR.”.
7010 CLAS0001 MESSAGE: Driver encountered a software problem.
CAUSE: While beginning a 10Base-T connect sequence on a
100VG-AnyLAN adapter card, the driver started to reset the PHY chip,
but encountered an error while trying to get or reset a timer
(“Cause” = 32-bit status from the call to vg_start_timer). This timer
was to be used to wait for the PHY reset to finish; the driver cannot
connect the link if a PHY timer cannot be started. If this error is
reported, it is because the driver has already encountered some other
error.
ACTION: Typically preceded by another error message giving better