NS3000/iX Error Messages Reference Manual (36923-90043)

254 Chapter16
100VG-AnyLAN and HP-PB 100Base-T Error Messages
SDI Driver Specific Status Values
If a crossover cable is being used, make sure it is correctly wired, and
that you have software version A00550B0 or later.
Check the configuration of the hub or switch port to which the adapter
card is connected. Adjust that configuration and, if necessary, use
NMMGR to adjust the configuration of the link, so that something will
match. If necessary, specify a forced speed and duplex setting, and
disable autonegotiation, at both ends.
7610 CLAS0001 MESSAGE: Driver encountered a hardware problem.
CAUSE: During a 10Base-T connect sequence on a 100VG-AnyLAN
adapter card, the driver attempted to adjust the duplex setting of the
LAN controller chip, but encountered an error trying to read from the
network command register on that chip (“Cause” = 32-bit status from
the call to vg_dio_read8). Most likely a powerfail has occurred.
ACTION: If a power failure has actually occurred, this error can be
ignored; the driver should recover automatically. But if the same
problem happens every time, see Appendix A , “Submitting a CR.
7640 CLAS0001 MESSAGE: Driver encountered a software problem.
CAUSE: During a 10Base-T connect sequence on a 100VG-AnyLAN
adapter card, after the link failed to connect, the driver started a retry,
but encountered an error while trying to stop and release a timer
(“Cause” = 32-bit status from the call to vg_stop_timer). This timer
was used to wait for the link to connect. If this error is reported, it is
because the driver has already encountered some other error.
ACTION: This is a warning that some timer resources may have been
lost. The link did not connect. Typically preceded by another error
message giving better information about the original cause; check log
data for that error and look it up also. Unless this happens constantly,
the system should continue to run, and the driver will probably retry
the connect. If the problem happens every time, see Appendix A ,
“Submitting a CR.
7670 CLAS0001 MESSAGE: Driver encountered a software problem.
CAUSE: During a 10Base-T connect sequence on a 100VG-AnyLAN
adapter card, after the link failed to connect, the driver started a retry,
but encountered an error while trying to stop and release a timer
(“Cause” = 32-bit status from the call to vg_stop_timer). This timer
was used to wait for the link to connect. If this error is reported, it is
because the driver has already encountered some other error.
ACTION: This is a warning that some timer resources may have been
lost. The link did not connect. Typically preceded by another error
message giving better information about the original cause; check log
data for that error and look it up also. Unless this happens constantly,
the system should continue to run, and the driver will probably retry
the connect. If the problem happens every time, see Appendix A ,
“Submitting a CR.