NS3000/iX Error Messages Reference Manual (36923-90043)

288 Chapter17
PCI 100Base-T Error Messages
SDI Driver Specific Status Values
following an error.
ACTION: None required, this status is informational only. An upper
layer protocol previously asked to be notified if a reset occurred in the
link driver, and such a reset has occurred, possibly as a result of
running diagnostics. However, an earlier error may have also occurred.
13 ($0D) MESSAGE: Powerfail detected.
CAUSE: The driver was notified of a power failure by the I/O system, or
detected all 1’s on a hardware register read, and, upon checking further,
saw that its hardware I/O address space was disabled, indicating a
powerfail had already occurred.
ACTION: Powerfails should not be detected on PCI platforms (due to
UPS support). Verify secure and stable power connections to the system
and if the problem continues, contact your HP representative.
14 ($0E) MESSAGE: Cannot release ADA memory object.
CAUSE: During shutdown, the driver requested the I/O system to
release a memory object, but received an error reply in response.
ACTION: This error should not occur. The driver may be confused, or
there is a system problem. However, the driver will ignore the error and
attempt to continue with the shutdown. If this happens frequently, see
Appendix A , “Submitting a CR,
15 ($0F) MESSAGE: Driver timed out waiting for ISR to shut down.
CAUSE: During link shutdown, the driver signaled the ISR to shut
down, then invoked the ISR. The driver then waited repeatedly for the
signal to clear, but it did not.
ACTION: This is an informational warning. The driver gave up waiting,
and continued with the rest of shutdown. If this happens frequently, see
Appendix A , “Submitting a CR.
16 ($10) MESSAGE: Retrying an operation.
CAUSE: An operation which failed or timed out is being tried again.
Several retries may be required. If the operation never succeeds, an
error may be reported and another action taken.
ACTION: No action required, this status is informational only.
17 ($11) MESSAGE: Cannot release a system plabel.
CAUSE: During the final link-close operation by an upper level
subsystem, the link module deconfigurator encountered an error while
trying to release the link’s write initiator procedure.
ACTION: This is an informational warning that some system memory
resources may have been lost. The module deconfigurator reported an
error, but attempted to continue with the close. If this happens every
time, see Appendix A , “Submitting a CR.