NS3000/iX Error Messages Reference Manual (36923-90043)

Chapter 18 407
PCI LAPBMUX Link Error Messages
SDI Driver Specific Status Values
1340 CLAS0001 MESSAGE: Cannot create a buffer pool.
CAUSE: During a link-open operation by an upper level subsystem, the
link module configurator encountered an error while trying to create an
outbound buffer pool (“Cause” = 32-bit status from the call to
bmgr_create_pool).
ACTION: The system may be low on available memory. The module
configurator cleaned up and returned an error to the subsystem.
Try stopping some applications or sessions and retry the operation. If
the problem persists, stop all networking and restart it, or restart the
system.
The buffer size and pool size are not configurable. If the problem still
occurs, there could be a problem with the buffer manager, see Appendix
A , “Submitting a CR.
1360 CLAS0001 MESSAGE: Cannot load a system routine.
CAUSE: During a link-open operation by an upper level subsystem, the
link module configurator encountered an error while trying to load code
for the write initiator procedure needed for the link type configured in
NMCONFIG (“Cause” = 32-bit status from the call to hpgetsysplabel).
ACTION: Probably not all software required to operate this type of link
is installed. Software was incorrectly installed, or you may need to
purchase additional software or install newer patches. Reinstall the
link software or contact your Hewlett-Packard Representative for
assistance.
1380 CLAS0001 MESSAGE: Cannot load driver plabel.
CAUSE: During a link-open operation by an upper level subsystem, the
link module configurator encountered an error while trying to load the
code for the driver (“Cause” = 32-bit status from the call to
io_get_mgr_entry).
ACTION: Probably not all software required to operate this type of link
is installed. The software was incorrectly installed, or you may need to
purchase additional software or install newer patches. Reinstall the
link software or contact your Hewlett-Packard Representative for
assistance.
1400 CLAS0001 MESSAGE: Unable to auto-configure underlying IO paths.
CAUSE: During a link-open operation by an upper level subsystem, the
link module configurator was attempting to create a new instance of the
link driver, but encountered an error when configuring the underlying
I/O paths (“Cause” = 32-bit status from the call to
io_configure_path).
ACTION: Probably not all software required to operate this type of link
is installed. The software was incorrectly installed, or you may need to
purchase additional software or install newer patches. Reinstall the