NS3000/iX Error Messages Reference Manual (36923-90043)

458 Chapter20
LAP-B Link Error Messages
LAP-B Link Shutdown Error Messages
LAP-B Link Shutdown Error Messages
This section describes error messages that might occur when you are
shutting down a LAP-B link. These messages appear when a
NETCONTROL STOP command calls the WAN_Kill_Module and
encounters an error. They are displayed on the HPe 3000 operator’s
console inq the following format:
WAN KILL MODULE (linkname) Message text
WAN KILL MODULE (linkname) Error ErrorNum, Status = Status,
Path: PhysPath
51 MESSAGE: Could not stop trace.
CAUSE: Trace may have been turned off via the LINKCONTROL command,
but the link software status indicates that it was on.
ACTION: Ignore this problem unless you are experiencing other
problems. Otherwise record the error information printed on the
console and contact your Hewlett-Packard representative.
52 MESSAGE: The link is not in the link table.
CAUSE: The link specified is not active.
ACTION: If the link name is incorrect, issue the command again with
the correct linkname. If the link name is correct, the link has already
been shutdown and no action is necessary.
53 MESSAGE: The link type is not SDLC, LAP-B, or RJE.
CAUSE: The caller of this module did not set the link type to one of
SDLC, LAP-B, or RJE.
ACTION: Please record the error information printed on the console and
contact your Hewlett-Packard representative.
54 MESSAGE: Could not delete the link from the link table.
CAUSE: The link name specified is not in the link table.
ACTION: Check that the link name is correct and try again. The link
may have already been shutdown.
55 MESSAGE: Could not unconfigure the link from the system.
CAUSE: The I/O subsystem does not have any record of this link being
active.
ACTION: Check that the link name is correct and try again. The link
may have already been shutdown.