NS3000/iX Error Messages Reference Manual (36923-90043)

Chapter 22 605
Logging Location Codes Continued
NFT Logging Location Codes
NFT Logging Location Codes
1 CLAS0002 MESSAGE: None
CAUSE: Attempt to open file NFCAT2 failed. Logging entry will also
contain a file system error.
ACTION: Act according to the file system error. For example, if the error
is “non-existent permanent file”, then the system manager should place
a copy of NFCAT2 in NET.SYS.
10 CLAS0002 MESSAGE: None
CAUSE: Attempt to open file NFTCAT2 failed. Logging entry will also
contain a file system error.
ACTION: Act according to the file system error. For example, if the error
is “non-existent permanent file”, then the system manager should place
a copy of NFTCAT2 in NET.SYS.
6 CLAS0003 MESSAGE: None
CAUSE: NFTCAT2 contains invalid configuration values.
ACTION: System manager should obtain a version of NFTCAT2 that has
valid configuration values and install it in NET.SYS. Another resource is
to change the configuration values in the existing NFTCAT2 file.
However, Hewlett-Packard does not recommend this procedure. If any
other internal errors (CLAS0000) are logged for the NFT module of the
Network Services subsystem, see Appendix A , “Submitting a CR,” of
this manual.
10 CLAS0003 MESSAGE: None
CAUSE: Incompatible version of NFTCAT2 installed.
ACTION: System manager should obtain correct version of NFTCAT2 and
install it in NET.SYS.