NS3000/iX Error Messages Reference Manual (36923-90043)

Chapter 22 643
Logging Location Codes Continued
Remote Link Manager Logging Location Codes
84 CLAS0002 MESSAGE: None
CAUSE: RLM could not free buffer.
ACTION: See Appendix A , “Submitting a CR,” of this manual.
85 CLAS0002 MESSAGE: None
CAUSE: RLM could not delete semaphore pool.
ACTION: See Appendix A , “Submitting a CR,” of this manual.
88 CLAS0004 MESSAGE: None
CAUSE: Link went down in an error condition.
ACTION: Check the status of the DTC.
90 CLAS0002 MESSAGE: None
CAUSE: RLM could not release semaphore.
ACTION: See Appendix A , “Submitting a CR,” of this manual.
92 CLAS0005 MESSAGE: None
CAUSE: DTC Link has gone down.
ACTION: Check the DTC X.25 card status.
93 CLAS0005 MESSAGE: None
CAUSE: X.25 Level3 Protocol on DTC is ready.
ACTION: None.
94 CLAS0003 MESSAGE: None
CAUSE: X.25 Level3 Protocol on DTC is not ready.
ACTION: Check the status of the DTC.
95 CLAS0003 MESSAGE: None
CAUSE: Host has lost contact with DTC.
ACTION: Check status of DTC.
96 CLAS0003 MESSAGE: None
CAUSE: Host has successfully communicated with DTC, but X.25
level 3 protocol on DTC is not ready.
ACTION: Check status of X.25 protocol on DTC. Possible causes include
bad/disconnected cable between DTC and switch/X.25 network, or the
switch/X.25 network is down. When problem is corrected, HP e3000 will
display additional logging messages and the network will be usable.
100 CLAS0002 MESSAGE: None
CAUSE: Could not create the RLM’s Port Data Area (PARM =
“create_object” status). Available virtual space may have been