NS3000/iX Error Messages Reference Manual (36923-90043)

Chapter 8 93
Remote File Access Error Messages
240 MESSAGE: LOCAL COMMUNICATION LINE NOT OPENED BY
OPERATOR. LOCAL COMMUNICATION LINE WAS NOT OPENED BY
OPERATOR. (Actual Message Displayed)
CAUSE: The RFA/RDBA service has not been started.
ACTION: Use the NETCONTROL START command to open the line.
242 MESSAGE: INTERNAL ERROR. INTERNAL DS SOFTWARE ERROR
ENCOUNTERED. (Actual Message Displayed)
CAUSE: This is an internal error.
ACTION: See Appendix A , “Submitting a CR,” of this manual.
246 MESSAGE: REMOTE NODE DISCONNECTED CONNECTION.
COMMUNICATIONS INTERFACE ERROR. REMOTE DISCONNECTED.
(Actual Message Displayed)
CAUSE: Remote node is no longer running on the network.
ACTION: Contact the system operator of the remote node.
249 MESSAGE: REMOTE SESSION ENVIRONMENT COULD NOT ADOPT
RFA SERVER. COMMUNICATIONS INTERFACE ERROR. REMOTE
DISCONNECTED. (Actual Message Displayed)
CAUSE: RFA was unable to initiate the RFA server in the remote
session.
ACTION: If the remote session was not aborted by the system operator,
then see Appendix A , “Submitting a CR,” of this manual.
255 MESSAGE: TRANSPORT ERROR ON CONNECTION.
COMMUNICATIONS INTERFACE ERROR. UNANTICIPATED
CONDITION. (Actual Message Displayed)
CAUSE: RFA lost connection with the RFA server on the remote system.
ACTION: If you attempted to use a newly supported RFA intrinsic, and
the version of RFA on the remote system is older than the version on
this system, then the remote system must be updated with compatible
versions of the Network Services. Otherwise, see Appendix A ,
“Submitting a CR,” of this manual.