NS3000/iX NMMGR Screens Reference Manual - Edition 8 (36922-90038)

Chapter 10 215
100VG-AnyLAN Network Interface Configuration Screens
Probe Protocol Configuration
Probe Protocol Configuration
The Probe Protocol Configuration screen (#92) in Figure 10-6 is
displayed when you press the
[Go To PROBE] function at the Protocol
Configuration screen (Figure 10-4). It is also displayed when you type
the path name:
@NETXPORT.NI.
NIname
.PROTOCOL.PROBE
in the command window of any screen and press the
[Enter] key, where
NIname is a configured VG100LAN NI.
Figure 10-6 Probe Protocol Configuration Screen
This screen allows you to configure the information required for the
probe protocol. The probe protocol exists on a 100VG-AnyLAN network
using the IEEE 802.3 protocol network to provide a means of
exchanging addressing and naming information between nodes. Press
the
[Save Data] function key to transfer the data displayed on the screen to
the configuration file you are creating or updating. Verify that the data
record has been created by checking that the Data flag is set to Y.