NS3000/iX NMMGR Screens Reference Manual - Edition 9 (36922-90040)

176 Chapter8
Token Ring Network Interface Configuration Screens
Network Interface Configuration
Network Interface Configuration
The Network Interface Configuration screen (#112) in Figure 8-2 is
displayed when you press the
[Go To NI] function key at the Network
Transport Configuration Selection screen (Figure 4-2). It is also
displayed when you type the path name:
@NETXPORT.NI
in the Command window of any screen and press the [Enter] key.
Figure 8-2 Network Interface Configuration Screen
Use the fields and the function keys of the select screen to perform the
desired action.
To define a new Token Ring NI, specify an NI name and NI type
TOKEN; then press the [
Add] function key. The path for the selected
NI name is added to the configuration file and the data screen on
that path is displayed. You can have a maximum of 12 NI’s per
system (one NI must be used for loopback). However, HP
supports only one active Token Ring NI per system.
To modify an existing NI configuration, specify the NI name; and
then press the
[Modify] function key. The data screen on the path for
the specified NI name is displayed.