NS3000/iX NMMGR Screens Reference Manual - Edition 9 (36922-90040)

196 Chapter9
FDDI Network Interface Configuration Screens
Network Interface Configuration
Network Interface Configuration
The Network Interface Configuration screen (#112) in Figure 9-2 is
displayed when you press the
[Go To NI] function key at the Network
Transport Configuration Selection screen (Figure 4-2). It is also
displayed when you type the path name:
@NETXPORT.NI
in the Command window of any screen and press the [Enter] key.
Figure 9-2 Network Interface Configuration Screen
Use the fields and the function keys of the select screen to perform the
desired action.
To define a new FDDI NI, specify an NI name and NI type FDDI;
then press the [
Add] function key. The path for the selected NI name
is added to the configuration file and the data screen on that path is
displayed. You can have a maximum of 12 NI’s per system (one
NI must be used for loopback). However, HP supports only
one active FDDI NI per system.
To modify an existing NI configuration, specify the NI name; and
then press the
[Modify] function key. The data screen on the path for
the specified NI name is displayed.