NS3000/iX NMMGR Screens Reference Manual - Edition 9 (36922-90040)

262 Chapter12
Logging Configuration Screens
Enabling Users for Individual Logging Classes
Enabling Users for Individual Logging Classes
The logging screens described in this chapter make it possible to
completely configure logging for all subsystems by traversing only six
screens. However, using these screens, it is not possible to configure
logging so that messages generated by specific logging classes are sent
to an individual user’s list device. The Logging Configuration: Class
Data screen (#67) is shown in Figure 12-9.
Figure 12-9 Logging Configuration: Class Data Screen
The following steps describe the method used to configuring users to
receive logging messages. Using this method, you can create a
configuration that allows messages from a single logging class, or a set
of classes, to be sent to a user’s list device.
To do so, you access and update the Logging Configuration Class Data
screen according to the following steps:
Step 1. Type the path name:
@LOGGING.SUBnnnn.CLASnnnn
in the command window of any screen and press the
[Enter] key, where
SUBnnnn is the subsystem ID and CLASnnnn is the class name of the
logging class you want directed to the user’s list device. The Logging
Configuration: Class Data screen shown in Figure 12-9 is displayed.
For example, subsystem 77, class 2 would be entered as:
@LOGGING.SUB0077.CLASS0002