NS3000/iX NMMGR Screens Reference Manual - Edition 9 (36922-90040)

Chapter 3 39
Link Configuration Screens
LAN Link Configuration
For some HP systems, you must specify a channel
number (ccc) and subchannel number (sss) in the form
ccc.sss while others require a bus converter number
followed by a slash (/) and then a channel number (ccc)
and subchannel number (sss) in the form b/ccc.sss.
If you are unsure of the slot location or of the physical
path number to configure for your system, see your
system documentation or consult your Hewlett-Packard
service representative.
Use factory-configured local station address?
(HP modifiable.) The LANIC board is supplied with a
48-bit station address. These are guaranteed to be
unique. Do not change the factory configured local node
address except on the specific instructions of your
Hewlett-Packard representative.
Default value: Y
Local station address
(modifiable.) This field is to be used only with specific
instructionsfromyour Hewlett-Packardrepresentative.
It allows you to enter a station address to replace the
factory configured address. The format must be
compatible with HP software requirements. Your
Hewlett-Packard representative will supply
instructions in the unlikely event that you need to