Owner's manual

Chapter 4 Accessories
19
Use these instructions to install an additional hard disk drive.
1. Backup your hard disk drive(s).
2. If necessary, shut down the network operating system.
3. Turn off the server and display and disconnect all external cables and
power cords.
4. Read the documentation included with the accessory for any special
handling or installation instructions.
5. Remove the NetServer cover.
6. Refer to the drive’s manuals to see if you must set jumpers or if there is a
special installation procedure to follow.
7. Remove the rear cooling fan from the rear of the chassis.
8. Pass the drive through the shelf with the connectors toward the NetServer
front, until the screw holes on the drive align with the holes in the chassis.
9. Secure it to the computer using the four ¼" screws provided with the
drive, two screws in each side (using screws other than those provided
may cause damage to the device). Replace the rear cooling fan.
CAUTION Do not use any size screw other than ¼-inch (6.5 mm) long,
6-32 machine screws to attach the hard disk drive to the tray.
Using any other size screw may result in permanent damage
to the disk drive.
10. Connect the power and data cables to the rear of the drive. The connectors
are keyed to fit one way only. See “IDE Cabling” for more information
about which connectors to use.
11. Replace the cover.