Chapter 9 Connecting the Monitor, Keyboard, Mouse, and UPS
78
Installing a Power Supply Module
The HP Netserver LP 2000r comes with one power supply module. A second
power supply module for redundancy is optional. If only one power supply
module is used, it must be installed in power supply bay 2, and a power supply
filler panel must be installed in the empty bay 1. Each power supply has its own
power cord (see Figure 9-2).
CAUTION Operating the HP Netserver without a power supply filler
panel in an empty power supply bay could cause excessive
EMI or thermal damage to the Netserver.
Power Supply Bay #1
Power Supply Bay #2
AC for Power Supply Bay #1
AC for Power Supply Bay #2
Figure 9-2. Power Supply Connectors
1. Remove the power supply filler panel from the empty power supply bay:
a. Pinch the release lever on the filler panel and pull the lever down.
b. Slide the filler panel out of the power bay. See Figure 9-3.
Save the power supply filler panel for future use. The filler panel must
be used in the empty power supply bay whenever you operate the HP
Netserver with a single power supply module.