User guide

Comment or clarificationError messageError code
between operations. Limit the number of such configuration
changes in the script.
Controller does not support SSP.1091
Controller requires physical drives to set
license keys.
1093
You cannot run a script in Input mode on internal controllers
that do not have slot information online. Systems running
Slot information is not available.1102
Microsoft Windows must have the System Management Driver
loaded.
Controller does not support license keys.1110
Invalid license key.1111
Controller has maximum number of license
keys.
1112
Controller requires non-failed physical
drives to set license keys.
1114
Controller is locked by another machine or
user.
2564
The scripted Method value is not valid.Invalid Method.2818
The scripted controller does not match any existing controllers.Invalid Controller.2819
Could not detect controller <text>.2820
This error applies to Input mode only. If no controllers are
detected in Capture mode, the capture file is empty.
No controllers detected.2821
The specified cache ratio is not supported by either the
controller or the current controller configuration.
Invalid read cache/write cache ratio.2822
Invalid rebuild priority.2823
This error message appears if the expand priority value
specified in the script is not supported. This message also
Invalid expand priority.2824
appears if expansion is not possible because the Expand
Priority feature is then not supported. Expansion might be
temporarily unavailable on a controller that normally supports
expansion if, for example, the cache battery has low charge,
another expansion or migration is already in progress, or the
array has the maximum supported number of physical drives.
The array ID is invalid.Invalid array.2825
The script file has commands that require an array, but no
array is specified.
Array not specified.2826
The scripted array ID is not the next ID in sequence, based
on the IDs of the existing arrays. For example, only array A
New array ID does not match the next
available array ID.
2827
exists and the script file specifies creation of array C (omitting
array B).
This error occurs in Configure mode when the array ID
specified in the script file already exists in the configuration.
In Configure mode, you can create only new arrays.
New array ID already exists.2828
The controller has no unassigned physical drives, or it already
has the maximum number of arrays or logical drives.
Cannot create array.2829
The controller does not support expansion, or the current
controller configuration is not expandable.
Cannot expand array.2830
42 Scripting Toolkit utilities