Security Solutions

value is an empty string, this will indicate to the monitor that
no email notifications sent.
MON_NOTIFICATION_SYSLOG (Default = 0)
This parameter defines whether the monitor will send
notifications to the syslog file. When the parameter is set to
0, the monitor will NOT send notifications to the syslog file.
When the parameter is set to 1, the monitor will send
notifications to the syslog file. If the parameter is not defined
(commented out), the default value is 0.
MON_NOTIFICATION_CONSOLE (Default = 0)
This parameter defines whether the monitor will send console
notifications. When the parameter is set to 0, the monitor
will NOT send console notifications. When the parameter
is set to 1, the monitor will send console notifications. If the
parameter is not defined (commented out), the default value
is 0.
AUTO_RESYNC This parameter defines the pre-defined resynchronization
actions that the monitor can perform when the package is
on the PVOL side and the monitor detects the Continuous
Access data replication link is down. If the variable is not
defined or commented, the default value of 0 is used.
Values:
0 — (Default) When the parameter is set to 0, the monitor
will not perform any resynchronization actions.
1 When the parameter is set to 1 and the data replication
link is down, the monitor will split the remote BC (if
configured) and try to resynchronize the device. Until the
resynchronization starts, the monitor will try to resynchronize
every polling interval. Once the device group has been
completely resynchronized, the monitor will resynchronize
the remote BC.
2 When the parameter is set to 2 and the data replication
link is down, the monitor will only try to perform
resynchronization if a file named MON_RESYNC exists in the
package directory (PKGDIR). The monitor will not perform
any operations to the remote BC (that is, split and
resynchronize the remote BC). Therefore, this setting is used
when you want to manage the remote BC
Package Attributes for Continentalcluster with Continuous Access EVA
This appendix lists all Package Attributes for Metrocluster with Continuous Access EVA. HP
recommends that you use the default settings for most of these variables, so exercise caution when
modifying them:
CLUSTER_TYPE This parameter defines the clustering environment in which
the script is used. You must set this to “metro” if this is a
Metrocluster environment and “continental” if this is a
Continentalclusters environment. A type of “metro” is
supported only when the HP Metrocluster product is installed.
A type of “continental” is supported only when the HP
Continentalclusters product is installed.
DTS PKG DIR If the package is a legacy package, this variable contains
the full path name of the package directory. If the package
is a modular package, this variable contains the full path
Package Attributes for Continentalcluster with Continuous Access EVA 95