(User Guide) Instruction Manual

HP deliverableHP SUM commandDescriptionScenario
VC IP address or DNS
name.
Need to select individual
firmware to update
Need to select individual
hardware devices to be
updated
Need to target VMware
host servers
Use this scenario when you:Scripted deployment to a
remote host
Online: Windows:
hpsum -s -target
Target1 -target
Are familiar with
command line tools
HP SPP
Run HP SUM from a
workstation and update a
HP Integrity Smart
Update Firmware
bundles
Target2 -username
User1 -password
PW1
Must perform a
customized, scripted
deployment
remote host over the network
using scripts.
Need to update multiple
targets, including HP-UX
Linux:
./hpsum -s -target
Target1 -target
Offline:
SmartStart Scripting
Toolkit (G7 and older)
11.31 or later, and OA,
VC, and server-based
firmware
Target2 -username
User1 -password
PW1
Scripting Toolkit
(Gen8 and older)
Need to update all
enclosure firmware
Need to target VMware
host servers
The HP SPP manages this
automatically
Use this scenario when you:Automatic deployment to
one or more servers in a HP
BladeSystem enclosure
Online:
None
Do not have an operating
system installed on a
server blade
Use the HP SPP with
embedded HP SUM to
Offline:
HP SPP
Want an automatic way
to deploy firmware
updates
deploy firmware updates to
one or more blades
automatically.
Do not require log files
or user interaction with
the installation process
Want to update multiple
blades in an enclosure in
a single operation
The same scenario as shown
in the “Interactive, graphical
Update an existing enclosure
manually
Online:
HP SPP
Windows:
hpsum
deployment to a remote
host” or “Scripted
Linux:
./hpsum
Offline:
HP SPP
deployment to a remote
host” scenarios discussed
previously in this table
Deploying firmware for HP ProLiant servers using the HP Service Pack for ProLiant
The SPP is a re-packaging of HP ProLiant system software and firmware for HP ProLiant BL/ML/DL/SL
servers and their options, and BladeSystem enclosures including OA,VC, and 3 Gb SAS switches
running supported Windows, Linux, and VMware operating systems. The single SPP image contains
a comprehensive collection of firmware and system software components including drivers, agents,
tools, utilities, and firmware that is tested, managed, and deployed together as a single solution.
The SPP includes HP SUM for deployment of the SPP components.
For a complete list of HP ProLiant systems and software supported by SPP, see the HP Service Pack
for ProLiant Release Notes on the HP website:
http://www.hp.com/go/spp/documentation