Installation Manual

HP Storage Essentials SRM 6.0 Installation Guide 129
IMPORTANT: Provide the SNMP credentials in the WBEM settings section on the System
Protocol Settings page (Options > Protocol Settings > System Protocol Settings). Only the
WBEM default credentials are passed from HP SIM to HP Storage Essentials. Any default
credential information you set up in regards to SNMP is not passed from HP SIM to HP
Storage Essentials.
1. Change the discovery setting for McDATA and Connectrix switches to SNMP following the
steps in ”Changing the Discovery Settings” on page 130.
2. Verify the following on the proxy and the switches accessible from the proxy:
The SNMP agent is enabled.
The read-only community string is configured.
3. To discover the proxy, enter the following information in HP SIM:
IP address or system name of the EFC Manager or Connectrix Manager you want to
discover.
User name. The default user name, which is public (the read-only community string). This
is the user name of the proxy.
Enter anything as a password; HP SIM does not allow an empty password field.
4. Make sure there are no port conflicts for receiving SNMP traps. When the management server
is configured to contact the proxy by SNMP, it receives events from the proxy in the form of
SNMP traps. By default, the management server uses port 162 to receive SNMP traps. If
another software package is using that port, the management server is unable to receive the
traps. For information about changing the port, see ”Changing the SNMP Trap Listener Port
and Community String for Switches Discovered with SNMP” on page 133.
5. Set up the proxy to send traps to the correct port. When you are using the SNMP setting to
discover a proxy, you must configure the SNMP agent on the proxy manager to send traps from
all switches managed by the proxy to the management server using the port you selected. For
more information, see the documentation for your proxy.
NOTE: The management server uses the Windows SNMP trap service when you run HP
SIM and HP Storage Essentials on a Windows server or when the property
cimom.winsnmpTrapService=true is set. The Windows SNMP trap service is not used
on Solaris servers.
Discovering McDATA and Connectrix Switches through a Direct Connection and SNMP
The management server uses SMI-S or SWAPI to discover a McDATA or Connectrix switch through
a proxy. If you want to discover McDATA or Connectrix switches directly, you must change the
discovery settings to SNMP before you begin the following steps. See ”Changing the Discovery
Settings” on page 130. See the support matrix for your edition for McDATA switch details (Help >
Documentation Center in HP Storage Essentials).
To discover a McDATA or Connectrix switch directly: