Installation Manual

Discovering Switches, Storage Systems, NAS Devices, and Tape Libraries138
To exclude EMC Symmetrix storage systems from a forced refresh:
1. Select Options >Storage Essentials > Manage Product Health > Advanced.
2. Click Show Default Properties at the bottom of the page.
3. Copy the following command.
#cimom.emc.skipRefresh=000183500570,000183500575
4. Click Close to return to the Advanced page.
5. Paste the copied text into the Custom Properties box.
6. Remove the pound (#) symbol in front of the property to make sure it is not commented out. Add
the serial numbers corresponding to the Symmetrix storage systems you want the refresh to skip.
Separate additional serial numbers with a comma, as shown by the following example:
cimom.emc.skipRefresh=000183500570,000183500575
where 000183500570 and 000183500575 are serial numbers for Symmetrix storage
systems.
NOTE: To find the serial number, double-click the storage system in System Manager, and
then click the Properties tab.
7. When you are done, click Save.
8. To force a refresh for elements that are not configured to skip the refresh, select the Force Device
Manager Refresh option on the Discovery Data Collection page.
9. Click Get Details to run discovery data collection.
Discovering EMC CLARiiON Storage Systems
The EMC Navisphere® CLI must be installed on the management server for the management server
to communicate with the CLARiiON® storage system. At the time this documentation was created,
EMC distributed the Navisphere CLI as part of the EMC Navisphere Software Suite. For Solaris,
you must install the Navisphere Disk Array Management Tool CLI (NAVICLI).
Contact your EMC representative for more information about obtaining the Navisphere CLI.
Distribution rights for the Navisphere CLI belong to EMC.
IMPORTANT: Before you discover a CLARiiON storage system, you must have already installed
all required software components for that CLARiiON storage system, such as the Navisphere Host
Agent. See the documentation for your storage system for more information.
In Navisphere Manager add one of the following to the privilege user section:
SYSTEM@<name_of_my_management_server>
SYSTEM@<IP_of_my_management_server>
where
name_of_my_management_server is the DNS name of the computer running the
management server software