User's Manual

You can return the local host name by entering %s after the device name. To return the user
name, enter %u after the device name. You can specify how many characters of the name is
returned in each case. For example, %.3s will return the first three characters of the local host
name, and %-.3s will return the last three characters.
To automatically assign a new device name for each successive connection, either enter %dN%
after the name, where N is a decimal value, or %xN%, where N is a hexadecimal value. Each
time the host requests the device name a counter will be substituted into the device name. If the
host rejects the device name as in use the counter will be incremented modulus N and the name
retried until all possibilities have been tried, at which point the emulation will report a device
name rejected error.
For example, TEST%d4% will give TEST1 on all connections until the host rejects the name as in
use, in which case TEST2 will be used. If this is already in use then TEST3 is used, or if already in
use then TEST0. These values are preserved over power off, so the first connection of any given
power on may not be TEST1. Assume that the start point is random.
When you achieve a TN3270E connection, the LU device name that you are connected as will be
displayed on the status line. If the specified device is rejected by the server or host, then an error
message box will be displayed indicating the reason.
Bind
Factory default: Unchecked
This determines whether the server is allowed to send the SNA Bind image and Unbind
notification to the emulator.
Responses
Factory default: Unchecked
When this is selected, positive and negative response handling is supported. It allows the server to
reflect to the emulator any and all definite, exception, and no response requests sent by the host
application.
SysReq
Factory default: Unchecked
When this option is selected, some (or all, depending on the server) of the functions of the
SysReq key will be emulated when the server is in an SNA environment.
LU Associate Name
Factory default: Unspecified
This enables you to specify the name of the terminal with which a printer is associated so that its
printer device name is assigned to this Telnet session.
LU1 & LU3 Printing
Factory default: Unchecked
These options apply when the 3287-1 printer is selected and they enable you to specify which
printer type(s) to support.
Setup Options
165