Advanced Server for UNIX Version 5.1B-4 ECO2 Release Notes (13158)

Unaligned access pid=1214 <lmx.srv> va=0x1405b5a79 pc=0x3ffbfbf1ea0
ra=0x3ffbfbf1e38 inst=0xa4290000
This problem is corrected in this release.
---------------------------------------------------------------
ASU and Windows 2003 Related Problem Descriptions and Solutions
---------------------------------------------------------------
Problem addressed:
If ASU is configured as a backup domain controller (BDC) to a Windows 2003 Server,
you cannot use the "net user" command to change user passwords. The following
error message is displayed:
Error 87 has occurred.
The parameter is incorrect.
This problem is corrected in this release.
-----------------------------
ASU Installation Instructions
-----------------------------
This ECO kit is a complete software kit that includes the features and
functionality of previous ASU software releases, and provides corrections
for the problems described in this document.
If you are installing the ASU software for the first time, change to the
directory where the ECO software was downloaded, enter the following
command, and follow the instructions on the screen:
# setld -l .
If you have ASU, ASDU, or PATHWORKS for DIGITAL UNIX subsets installed,
you must use the Tru64 UNIX setld command to deinstall those subsets
before you install the subsets in this ECO kit.
The following steps show you how to use the setld command to deinstall
ASU, ASDU, or PATHWORKS subsets and install the ECO software. HP recommends
that you back up your "/usr/net/servers/lanman" directory before
beginning this process: