Compaq StorageWorks HSG60 ACS Solution Software V8.6 for Compaq Tru64 UNIX Installation and Configuration Guide

Configuration Procedures 5–7
11. Verify that all commands have taken effect. Use the following command:
SHOW THIS
Verify node ID, allocation class, SCSI version, failover mode, identifier, and port
topology. Following is a sample result of a SHOW THIS command, with the areas of
interest in bold.
Controller:
HSG60 (C) DEC ZG09030200 Software V86L, Hardware 0000
NODE_ID = 5000-1FE1-0000-0000
ALLOCATION_CLASS = 0
SCSI_VERSION = SCSI-3
Not configured for dual-redundancy
Device Port SCSI address 7
Time: 10-Mar-1999:12:30:34
Command Console LUN is lun 0
Host PORT_1:
Reported PORT_ID = 5000-1FE1-0000-0001
PORT_1_TOPOLOGY = FABRIC (fabric up)
Address = 210313
Host PORT_2:
Reported PORT_ID = 5000-1FE1-0000-0002
PORT_2_TOPOLOGY = FABRIC (fabric up)
Address = 210513
NOREMOTE_COPY
.......
12. Turn on the switches, if not done previously.
If you want to communicate with the FC switches through Telnet, set an IP address for
each switch. See the manuals that came with the switches for details.
Plug in the FC Cable and Verify Connections
13. Plug in the Fibre Channel cable from the first adapter in the first host into the switch.
Enter a SHOW connections command to view the connection table:
SHOW CONNECTIONS