Compaq StorageWorks HSG60 ACS Solution Software V8.6 for Compaq Tru64 UNIX Installation and Configuration Guide

Planning a Subsystem 1–27
Controller B, port 1—worldwide name + 1, for example 5000-1FE1-FF0C-EE01
Controller B, port 2—worldwide name + 2, for example 5000-1FE1-FF0C-EE02
Controller A, port 1—worldwide name + 3, for example 5000-1FE1-FF0C-EE03
Controller A, port 2—worldwide name + 4, for example 5000-1FE1-FF0C-EE04
Use the CLI command, SHOW this_controller/other_controller to display the subsystem’s
worldwide name.
Restoring Worldwide Names (Node IDs)
If a situation occurs that requires you to restore the worldwide name, you can restore it
using the worldwide name and checksum printed on the sticker on the frame into which
the controller is inserted.
Figure 1–13 shows the placement of the worldwide name label for the Model 2100
enclosure.
Figure 1–13. Placement of the worldwide name label on the Model 2100 enclosure
Unit Worldwide Names (LUN IDs)
In addition, each unit has its own worldwide name, or LUN ID. This is a unique, 128-bit
value that the controller assigns at the time of unit initialization. It cannot be altered by the
user but does change when the unit is reinitialized. Use the SHOW command to list the
LUN ID.
C
1 Node ID
(Worldwide name)
2 Checksum
CXO7195A
WWN INFORMATION
P/N:
WWN:
Checksum:
NNNN – NNNN – NNNN – NNNN
NN
S/N:
1
2