HP Tru64 UNIX and TruCluster Server Version 5.1B-5 Patch Summary and Release Notes (March 2009)

Corrects a performance problem on systems with many sensors by reducing the
polling frequency.
Prevents a long boot pause on AlphaServer GS1280 systems with large disk and
sensor counts.
Fixes issues with envmond with respect to log messages and the execution of
shutdown scripts.
Patch 27030.00
OSFEXAMPLES540
Eliminates the use of a /tmp file in a SysMan CLI example.
Patch 27031.00
OSFEXER540
Corrects the memory exerciser user.syslog message from "Started" to "Stopped".
Corrects a message from memx.
Patch 27034.00
OSFHWBASE540
Enhances hwmgr show functionality for scsi path information.
Provides for FCP-2 Link Level Error Recovery for tape operations so that tape I/O
can be successfully performed during periods of link errors, noisy lines, bit errors,
and lost or corrupted data frames.
Enables Tru64 UNIX to work with tape devices that do not support non-tagged
commands.
Fix for netstat trying to resolve the IP address 0.0.0.0 (INADDR_ANY) to a
hostname.
Fix to netstat, kdbx displaying partial kernel addresses.
Fixes several I/O error handling and error reporting problems in the Tru64 Emulex
Fibre Channel driver that can result in inefficient error handling or misleading
error log entries.
Updates the bcm driver to V1.0.22 to fix issues with IPv6 and SNMP
Fixes many small problems with the dsfmgr command.
Fixes the hwmgr command to show path state correctly.
Fixes numerous issues in the driver for DEGXA Gigabit Ethernet adapters, including
the DS25 onboard 10/100/1000 port.
Corrects a problem in which information from the hwmgr -view transaction -cluster
command for a node on a cluster may not be displayed.
Corrects some command-parsing irregularities in hwmgr that may cause options
like -category and -cluster to be confused.
3.4 Summary of Base Operating System Patches 153