HP Tru64 UNIX and TruCluster Server Version 5.1B-5 Patch Summary and Release Notes (March 2009)

# /usr/sbin/showfile mountpoint/.tags/M-6
Id Vol PgSz Pages XtntType Segs SegSz I/O Perf File
fffffffa.0000 1 16 1 simple ** ** ftx 100% M-6
See the fixfdmn(8), showfile(8), and showfile(8) reference pages for information about
using these commands.
2.2.1.10 Possible Errors Seen After Kit Installation
The following problems have been known to occur after Version 5.1B-4 or higher has
been installed:
The Common Data Security Architecture (CDSA), IP Security Protocol (IPsec), or
Single Sign-On (SSO) do not work.
The following error message is displayed during boot time:
CSSM_ModuleLoad: CSSM error 4107
If you experience these problems, make sure that the following command line has been
executed:
# /usr/sbin/cdsa/mod_install -f -i -s \
/usr/lib/cdsa/libt64csp.so -d /usr/lib/cdsa/
2.2.1.11 Message Seen During Reboot Can Be Ignored
The following error message will be displayed after you reboot your system the first
time after installing Version 5.1B-4 or higher:
AllowCshrcSourcingWithSubsystems is not valid
ForcePTTYAllocation is not valid
IdentityFile is not valid
AuthorizationFile is not valid
These messages are caused by a new version of SSH included in Version 5.1B-4 or
higher. They do not pose a problem and can be ignored.
2.2.2 Kit Removal Release Notes
The following sections describe actions you have to take if you decided to uninstall
Version 5.1B-4 or higher. Read each section before running the patch deletion procedure.
2.2.2.1 Some Patch Kits Cannot Be Removed
You cannot remove a patch kit on systems that have New Hardware Delivery 7 (NHD-7)
kit installed when either of the following conditions exist:
28 Kit Installation and Removal