Compaq StorageWorks HSG60 ACS Solution Software V8.6 for Compaq Tru64 UNIX Installation and Configuration Guide

5–2 HSG60 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration Guide
To install a controller or cache module and the PCMCIA card, see the Compaq
StorageWorks HSG60 Array Controller ACS Version 8.6 Maintenance and Service
Guide.
Establishing a Local Connection
A local connection is required to configure the controller until a command console
LUN (CCL) is established using the CLI. Communication with the controller can be
through the CLI or SWCC.
The maintenance port, as shown in Figure 51, provides a way to connect a maintenance
terminal. The maintenance terminal can be an EIA-423 compatible terminal or a computer
running a terminal emulator program. The maintenance port accepts a standard RS-232
jack. The maintenance port cable shown in Figure 51 has a 9-pin connector molded onto
the end for a PC connection. If you need a terminal connection or a 25-pin connection, you
can order optional cabling.
Figure 5–1. Maintenance port connection
CAUTION: The maintenance port generates, uses, and can radiate radio-frequency
energy through its cables. This energy may interfere with radio and television
reception. Disconnect all maintenance port cables when not communicating with the
controller through the local connection.
1 Maintenance Port Cable 2 Maintenance Port
CXO7181A