Compaq StorageWorks HSG60 ACS Solution Software V8.6 for Compaq Tru64 UNIX Installation and Configuration Guide

5–16 HSG60 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration Guide
NOTE: See the ADD MIRRORSET command in the Compaq StorageWorks HSG60 Array
Controller ACS Version 8.6 CLI Reference Guide for a description of the mirrorset switches.
2. Initialize the mirrorset, specifying any desired switches:
INITIALIZE MIRRORSET-NAME SWITCHES
See Initialization Switches on page 223 for a description of the initialization
switches.
3. Verify the mirrorset configuration:
SHOW MIRRORSET-NAME
4. Assign the mirrorset a unit number to make it accessible by the hosts. See Assigning
Unit Numbers and Unit Qualifiers on page 519.
For example:
The commands to create Mirr1, a mirrorset with two members (DISK10000 and
DISK20000), and to initialize it using default switch settings:
ADD MIRRORSET MIRR1 DISK10000 DISK20000
INITIALIZE MIRR1
SHOW MIRR1
Configuring a RAIDset
1. Create the RAIDset by adding its name to the controller's list of storagesets and
specifying the disk drives it contains. Optionally, you can specify RAIDset switch
values:
ADD RAIDSET RAIDSET-NAME DISKNNNNN DISKNNNNN DISKNNNNN SWITCHES
NOTE: See the ADD RAIDSET command in the Compaq StorageWorks HSG60 Array Controller
ACS Version 8.6 CLI Reference Guide for a description of the RAIDset switches.
2. Initialize the RAIDset, specifying any desired switches:
INITIALIZE RAIDSET-NAME SWITCH
NOTE: Compaq recommends that you allow initial reconstruct to complete before allowing I/O
to the RAIDset. Not doing so may generate forced errors at the host level. To determine whether
initial reconstruct has completed, enter SHOW RAIDSET FULL.
See Initialization Switches on page 223 for a description of the initialization
switches.
3. Verify the RAIDset configuration:
SHOW RAIDSET-NAME