Compaq StorageWorks HSG60 ACS Solution Software V8.6 for Compaq Tru64 UNIX Installation and Configuration Guide

7–2 HSG60 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration Guide
Figure 7–1. Example storage map
The example system shown in Figure 72, contains three non-clustered TRU64_UNIX
hosts. The port 1 link is separate from the port 2 link (that is, ports 1 of both controllers are
on one loop or fabric, and port 2 of both controllers are on another) therefore, each adapter
has two connections.
From the hosts point of view, each host will have four paths to its own virtual disks.The
figure shows a representative multiple-bus failover configuration. Restricting the access of
unit D101 to host BLUE can be done by enabling only the connections to host BLUE. At
least two connections must be enabled for multiple-bus failover to work. For most
operating systems, it is desirable to have all connections to the host enabled.
Model 4214R Disk Enclosure Shelf 1 (single-bus)
Bay1234567891011121314
SCSI
ID
00 01 02 03 04 05 08 09 10 11 12 13 14 15
DISK
ID
D0
R1
D0
R1
D0
R1
D1
S1
M1
D1
S1
M1
D1
S1
M2
D1
S1
M2
D100
M3
D100
M3
D120
S2
D120
S2
Spare
not supported
not supported
DISK10000
DISK10100
DISK10200
DISK10300
DISK10400
DISK10500
DISK10800
DISK10900
DISK11000
DISK11100
DIS112000
DISK11300
Model 4214R Disk Enclosure Shelf 2 (single-bus)
Bay1234567891011121314
SCSI
ID
00 01 02 03 04 05 08 09 10 11 12 13 14 15
DISK
ID
D0
R1
D0
R1
D0
R1
D1
S1
M1
D1
S1
M1
D1
S1
M2
D1
S1
M2
D100
M3
D100
M3
D120
S2
D120
S2
Spare
not supported
not supported
DISK20000
DISK20100
DISK20200
DISK20300
DISK20400
DISK20500
DISK20800
DISK20900
DISK21000
DISK21100
DISK21200
DISK21300