HP Tru64 UNIX and TruCluster Server Version 5.1.B-4 Patch Summary and Release Notes (13156)

Fixes the fwtmp command so it does not display invalid (negative) PIDs when the number
of decimal digits of PID value exceeds 5.
Corrects a potential security vulnerability where, under certain circumstances, system
integrity may be compromised. This may be in the form of improper file or privilege
management.
Corrects an error in the script in lastlogin.sh.
Makes start up scripts in /sbin/init.d world readable.
Corrects the following problems found in accounting commands:
— Resolves the differences in the CPU time and connect time found during the conversion
of accounting reports from ASCII format to binary and again back to ASCII.
— Resolves the differences in CPU time found in the output of the acctcom and acctmerg
commands for the same input file.
— Fixes the way accounting files are referenced using CDSLs.
— Corrects the display of the header from acctcom when accounting is first started.
— Corrects an error message during execution of the runacct command.
— Enables acctcom to read more than one input file.
— Enables acctcom to work with pipes.
Fixes the acctcom command with respect to the display of tty lines.
Corrects a problem in which accounting reports show the wrong connection time for the
users who remain logged in during the execution of runacct.
Enables the acctcon1 command to calculate the connect time for local logins in case of run
level changes.
Patch 27002.00
OSFADVFS540
Corrects a potential security vulnerability where, under certain circumstances, system
integrity may be compromised. This may be in the form of improper file access.
Provides enhancements for file system suitlets.
Improves AdvFS informational messages as follows:
— Advscan reports if a domain has all of its volumes, but they are stored in a different
directories. This scenario will cause mount to fail.
— The AdvFS I/O error message includes the location of a file that will help users to
translate the error number into an error message.
Prevents erroneous display of DMAPI messages while using the showfile command.
Fixes a problem in which the verify utility core dumps if it encounters a specific type of
metadata inconsistency.
Improves the information provided in an error message that is displayed when the chfile
command to display an informative error message if it fails while trying to enable data
logging.
Modifies the nvbmtpg utility to display all the data in a specified mcell only if the -v option
is selected.
Fixes a problem where defragmentation can fail if the process can not obtain enough memory.
Provides support for Smart Array disk controllers. Without this patch, if the Smart Array
product is installed on the system, the SysMan Station hardware view will fail to operate.
Corrects the error message returned when trying to migrate striped files when the -s option
is omitted.
3.4 Summary of Base Operating System Patches 75