HSG80 ACS Solution Software Version 8.7 for Compaq Tru64 UNIX Installation and Configuration Guide

Table Of Contents
FC Configuration Procedures
5–8 HSG80 ACS Solution Software Version 8.7 for Compaq Tru64 UNIX Installation and
Configuration Guide
The following sample is a result of a SHOW THIS command, with the areas of interest
in bold.
Controller:
HSG80 ZG94214134 Software V8.7, Hardware 0000
NODE_ID = 5000-1FE1-0007-9750
ALLOCATION_CLASS = 0
SCSI_VERSION = SCSI-3
Configured for dual-redundancy with ZG9421461
In dual-redundant configuration
Device Port SCSI address 7
Time: 10-Mar-2002:12:30:34
Command Console LUN is disabled
Smart Error Eject Disabled
Host PORT_1:
Reported PORT_ID = 5000-1FE1-0007-9751
PORT_1_TOPOLOGY = FABRIC (fabric up)
Address = 7D4000
Host PORT_2:
Reported PORT_ID = 5000-1FE1-0007-9752
PORT_2_TOPOLOGY = FABRIC (standby)
Address = 210513
NOREMOTE_COPY
Cache:
512 megabyte write cache, version 0022
Cache is GOOD
No unflushed data in cache
CACHE_FLUSH_TIMER = DEFAULT (10 seconds)
Mirrored Cache:
Not enabled
Battery:
NOUPS
FULLY CHARGED
Expires: 25-JUN-2003
.......