HSG80 ACS Solution Software Version 8.7 for Compaq Tru64 UNIX Installation and Configuration Guide

Table Of Contents
FC Configuration Procedures
5–16 HSG80 ACS Solution Software Version 8.7 for Compaq Tru64 UNIX Installation and
Configuration Guide
Verify Installation
To verify installation for your Tru64_UNIX host, enterone of the following
commands:
For V4.0G Use
file /dev/rrx*c | grep HSG80
For V5.1x Use
file /dev/cport/ *
Your host computer should report one CCL device special file for each HSG80
configured.
Configuring Devices
The disks on the device bus of the HSG80 can be configured manually or with the
CONFIG utility. The CONFIG utility is easier. Invoke CONFIG with the following
command:
RUN CONFIG
WARNING: It is highly recommended to use the CONFIG utility only at reduced
I/O loads.
CONFIG takes about two minutes to discover and to map the configuration of a
completely populated storage system.
Configuring Storage Containers
For a technology refresher on this subject, refer to “Choosing a Container Type,” page
2–14.
In choosing a container, you choose between independent disks (JBODs) or one of
several storageset types, as shown in Figure 5–4. The independent disks and the
selected storageset may also be partitioned.
The following configurations are detailed in the following section:
“Configuring a Stripeset” on page 5–17