HSG80 ACS Solution Software Version 8.7 for Compaq Tru64 UNIX Installation and Configuration Guide

Table Of Contents
FC Configuration Procedures
5–27HSG80 ACS Solution Software Version 8.7 for Compaq Tru64 UNIX Installation and
Configuration Guide
5–27
Verifying Storage Configuration from Host
This section briefly describes how to verify that multiple paths exist to virtual disk
units under Tru64 UNIX V5.1x.
After configuring units (virtual disks) through either the CLI or SWCC, access the
new storage by using one of the following methods:
Issuing the following command to rescan the bus:
# hwmgr -scan scsi
# dsfmgr -k
or
Restart the host
After the host restarts, verify that the disk is correctly presented to the host. The
command to use consists of the following syntax:
# hwmgr -view dev
The disk information returned is shown in the following table:
HWID: Device
Name
Mfg Model Location
123:
/dev/disk/dsk56c
DEC HSG80C
CL
bus-5-targ-0-lun-
0
124:
/dev/disk/dsk57c
DEC HSG80 bus-6-targ-0-lun-
1
125:
/dev/disk/dsk58c
DEC HSG80 bus-5-targ-0-lun-
2
126:
/dev/disk/dsk59c
DEC HSG80 bus-5-targ-0-lun-
60
127:
/dev/disk/dsk60c
DEC HSGCCL bus-5-targ-10-lun
-0
128:
/dev/disk/dsk61c
DEC HSG80 bus-5-targ-10-lun
-60
129:
/dev/disk/dsk62c
DEC HSG80 bus-5-targ-10-lun
-61
130:
/dev/disk/dsk63c
DEC HSG80 bus-5-targ-10-lun
-62