# hostname
rye.zk3.dec.com
# hwmgr -view devices
HWID: Device Name Mfg Model Location
------------------------------------------------------------------
-----
4: /dev/kevm
44: /dev/disk/floppy0c 3.5in floppy fdi0-unit-0
53: /dev/disk/cdrom0c DEC RRD47 (C) DEC bus-0-targ-5-lun-0
54: /dev/disk/dsk0c DEC HSG80 IDENTIFIER=1
55: /dev/disk/dsk1c DEC HSG80 IDENTIFIER=2
56: /dev/disk/dsk2c DEC HSG80 IDENTIFIER=3
57: /dev/disk/dsk3c DEC HSG80 IDENTIFIER=4
58: /dev/disk/dsk4c DEC HSG80 IDENTIFIER=5
59: /dev/disk/dsk5c DEC HSG80 IDENTIFIER=6
60: /dev/disk/dsk6c DEC HSG80 IDENTIFIER=7
61: /dev/ntape/tape0 DEC TLZ10 (C) DEC bus-0-targ-4-lun-0
62: /dev/cport/scp0 HSG80CCL bus-4-targ-0-lun-0
125: /dev/dmapi/dmapi
However, because SWCC looks at storage from the controller's viewpoint, units D8,
D9, and D10 appear in the Storage Window for rye even though member rye cannot
directly access these units, as shown in the Example of Confusing Storage Display.
As another example, if you use the /usr/opt/SWCCx/scripts/swcc_config
configuration tool to make a change to the storage subsystem information and restart
the agent on one member, you must also use the /usr/opt/SWCCx/scripts/swcc_config
configuration tool to restart the agent on all other members. If you do not do this, the
Navigation Window for the two members can show a discrepancy.