HSG80 ACS Solution Software Version 8.7 for Compaq Tru64 UNIX Installation and Configuration Guide
Table Of Contents
- HSG80 ACS Solution Software Version 8.7 for Compaq Tru64 UNIX Installation and Configuration Guide
- About this Guide
- 1- Planning a Subsystem
- Defining Subsystems
- What is Failover Mode?
- Selecting a Cache Mode
- Enabling Mirrored Caching
- What is the Command Console LUN?
- Determining Connections
- Assigning Unit Numbers
- What is Selective Storage Presentation?
- 2- Planning Storage Configurations
- Where to Start
- Determining Storage Requirements
- Configuration Rules for the Controller
- Addressing Conventions for Device PTL
- Choosing a Container Type
- Creating a Storageset Profile
- Planning Considerations for Storageset
- Changing Characteristics through Switches
- Specifying Storageset and Partition Switches
- Specifying Initialization Switches
- Specifying Unit Switches
- Creating Storage Maps
- 3- Preparing the Host System
- Installing RAID Array Storage System
- Making a Physical Connection
- Preparing LUNs for Access by Tru64 UNIX FileSystem
- DECsafe Available Server Environment (ASE)
- HSG80 Units and Tru64 UNIX Utilities
- Solution Software Upgrade Procedures
- New Features, ACS 8.7 for Tru64
- 4- Installing and Configuring HSG Agent
- 5- FC Configuration Procedures
- Establishing a Local Connection
- Setting Up a Single Controller
- Setting Up a Controller Pair
- Configuring Devices
- Configuring Storage Containers
- Assigning Unit Numbers and Unit Qualifiers
- Configuration Options
- Verifying Storage Configuration from Host
- 6- Using CLI for Configuration
- 7- Backing Up, Cloning, and Moving Data
- A- Subsystem Profile Templates
- Storageset Profile
- Storage Map Template 1 for the BA370 Enclosure
- Storage Map Template 2 for the second BA370 Enclosure
- Storage Map Template 3 for the third BA370 Enclosure
- Storage Map Template 4 for the Model 4214R Disk Enclosure
- Storage Map Template 5 for the Model 4254 Disk Enclosure
- Storage Map Template 6 for the Model 4310R Disk Enclosure
- Storage Map Template 7 for the Model 4350R Disk Enclosure
- Storage Map Template 8 for the Model 4314R Disk Enclosure
- Storage Map Template 9 for the Model 4354R Disk Enclosure
- B- Installing, Configuring, and Removing the Client
- C- SWCC Agent in TruCluster Environment
- SWCC Overview
- Running the SWCC Agent on a V4.0G Cluster
- Running the SWCC Agent under ASE Services
- Running the SWCC Agent on a V5.x Cluster
- Problems with Running the Agent on Multiple Clusters
- Configure the Controller
- Use Multiple-Bus Failover Mode
- Verify That the HSG80/HSG60 Unit Offsets Are Zero
- Install and Run the Agent on One Cluster Member
- Example of Installing the Agent on a Cluster Member
- Create the CAA Action Script
- Create the CAA Resource
- Glossary
- Index
Index
Index–4 HSG80 ACS Solution Software Version 8.7 for Compaq Tru64 UNIX Installation and
Configuration Guide
geometry 2–33
NOSAVE_CONFIGURATION
2–32
SAVE_CONFIGURATION
2–32
Insight Manager
B–13
installation
controller verification
5–9, 5–16
invalid network port assignments
B–8
there is no disk in the drive message
B–9
installation verification
CLI commands
5–9, 5–16
installing
Agent
4–5
integrating SWCC
B–13
invalid network port assignments
B–8
iostat
Tru64 UNIX utility
3–13
J
JBOD 2–15
L
LOCATE
find devices
2–34
location
cache module
1–2, 1–3
controller
1–2, 1–3
LUN IDs
general description
1–29
LUN presentation
1–18
LUNs
creating a filesystem
3–8
creating partitions using disklabel
3–7
preparing for use by filesystem
3–6
M
maintenance port connection
establishing a local connection
5–2
illustrated
5–2
mapping storagesets
2–34
messages
there is no disk in the drive
B–9
mirrored caching
enabling
1–10
illustrated
1–11
mirrorset switches
changing
fabric topology
5–26
mirrorsets
planning considerations
2–21
important points
2–22
switches
2–29
Model 2200 Storage Maps
examples
2–7
moving storagesets
7–5
mulitple-bus failover
restricting host access by offsets
1–26
multiple-bus failover
1–7
ADD CONNECTIONS command
1–19
ADD UNIT command
1–19
ADD UNITcommand
1–19
CLI configuration procedure
fabric topology
6–4
fabric topology
preferring units
5–23
fabric topology configuration
cabling
5–10
host connections
1–19
restricting host access
1–24
disabling access paths
1–24
SET CONNECTIONS command
1–19
SET UNITcommand
1–19
N
network port assignments B–8
new features
3–20
node IDs
1–27
restoring
1–28
NODE_ID
worldwide name
1–27
NOSAVE_CONFIGURATION
2–32
O
offset
LUN presentation
1–18
restricting host access
multiple-bus fafilover