HSG80 ACS Solution Software Version 8.7 for Compaq Tru64 UNIX Installation and Configuration Guide

Table Of Contents
Planning a Subsystem
1–12 HSG80 ACS Solution Software Version 8.7 for Compaq Tru64 UNIX Installation and
Configuration Guide
Serves as a communications device for the HS-Series Agent. The CCL identifies
itself to the host by a unique identification string.
In dual-redundant controller configurations, the commands described in the following
sections alter the setting of the CCL on both controllers. The CCL is enabled only on
host port 1. At least one storage device of any type must be configured on host port 2
before installing the Agent on a host connected to host port 2.
Select a storageset that you plan to configure and that is not likely to change. This
storageset can be used by the Agent to communicate with the RAID Array. Deleting
this storageset (LUN) later breaks the connection between the Agent and the RAID
Array.
Determining the Address of the CCL
CCL is enabled by default. Its address can be determined by entering the following
CLI command:
HSG80 > SHOW THIS_CONTROLLER
Enabling/Disabling the CCL in SCSI-2 Mode
Enabling the CCL
To enable the CCL, enter the following CLI command:
HSG80 > SET THIS_CONTROLLER COMMAND_CONSOLE_LUN
Disabling the CCL
To disable the CCL, enter the following CLI command:
HSG80 > SET THIS_CONTROLLER NOCOMMAND_CONSOLE_LUN
To see the state of the CCL, use the SHOW THIS CONTROLLER/ OTHER CONTROLLER command.
Because the CCL is not an actual LUN, the
SHOW UNITS command will not display the
CCL location.
Enabling/Disabling CCL in SCSI-3 Mode
The CCL is enabled all the time. There is no option to enable/disable.