Compaq StorageWorks HSG60 ACS Solution Software V8.6 for Compaq Tru64 UNIX Installation and Configuration Guide

Configuration Procedures 5–9
For V5.1x use:
file /dev/cport/ *
Your host computer should report one CCL device special file for each HSG60 configured.
Setting Up a Controller Pair
Power Up and Establish Communication
1. Connect the computer or terminal to the controller as shown in Figure 51. The
connection to the computer is through the COM1 or COM2 ports.
2. Turn on the computer or terminal.
3. Apply power to the storage subsystem.
4. Configure the computer or terminal as follows:
9600 baud
8 data bits
1 stop bit
no parity
5. Press Enter. A copyright notice and the CLI prompt appear, indicating that you
established a local connection with the controller.
Cabling a Controller Pair
The cabling for a controller pair failover showing one HBA per server with HSG60
controller in transparent failover mode is shown in Figure 53.
NOTE: It is a good idea to plug only the controller cables into the switch. The host cables are
plugged into the switch as part of the configuration procedure (“Configuring a Controller Pair
Using CLI,” page 5–10).