Compaq StorageWorks HSG60 ACS Solution Software V8.6 for Compaq Tru64 UNIX Installation and Configuration Guide

5–12 HSG60 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration Guide
6. Set the topology for the controller. If both ports are used, set topology for both ports:
SET THIS PORT_1_TOPOLOGY=FABRIC
SET THIS PORT_2_TOPOLOGY=FABRIC
If the controller is not factory-new, it may have another topology set, in which case
these commands will result in an error message. If this happens, take both ports offline
first, then reset the topology:
SET THIS PORT_1_TOPOLOGY=OFFLINE
SET THIS PORT_2_TOPOLOGY=OFFLINE
SET THIS PORT_1_TOPOLOGY=FABRIC
SET THIS PORT_2_TOPOLOGY=FABRIC
Restart the Controller
7. Restart the controller, using the following command:
RESTART THIS
It takes about one minute for the CLI prompt to come back after a RESTART
command.
Set Time and Verify All Commands
8. Set the time on the controller using the following syntax:
SET THIS TIME=DD-MMM-YYYY:HH:MM:SS
9. Use the FRUTIL utility to set up the battery discharge timer. Enter the following
command to start FRUTIL:
RUN FRUTIL
When FRUTIL asks if you intend to replace the battery, answer Y:
Do you intend to replace this controller's cache battery? Y/N [N] Y
FRUTIL will print out a procedure, but will not give you a prompt. Ignore the
procedure and just press Enter.
10. Set up any additional optional controller settings, such as changing the CLI prompt.
See the
SET this_controller/other controller command in the Compaq StorageWorks
HSG60 Array Controller ACS Version 8.6 CLI Reference Guide for the format of
optional settings.
11. Verify that all commands have taken effect. Use the following command:
SHOW THIS