Compaq StorageWorks HSG60 ACS Solution Software V8.6 for Compaq Tru64 UNIX Installation and Configuration Guide

Chapter 6
Verifying Storage Configuration from the Host
This chapter briefly describes how to verify that multiple paths exist to virtual disk units
under Tru64 UNIX V5.1x.
After configuring units (virtual disks) through either the CLI or SWCC, access the new
storage by performing one of the following methods:
Issuing the following command to rescan the bus:
# hwmgr scan scsi
or
Restarting the host.
After the host restarts, verify that the disk is correctly presented to the host. The command
to use consists of the following syntax:
# hwmgr view dev
The disk information returned is shown on the following table:
HWID: Device Name Mfg Model Location
123: /dev/disk/dsk56c DEC HSG60CCL bus-5-targ-0-lun-0
124: /dev/disk/dsk57c DEC HSG bus-6-targ-0-lun-1
125: /dev/disk/dsk58c DEC HSG bus-5-targ-0-lun-2
126: /dev/disk/dsk59c DEC HSG bus-5-targ-0-lun-60
127: /dev/disk/dsk60c DEC HSGCCL bus-5-targ-10-lun-0
128: /dev/disk/dsk61c DEC HSG bus-5-targ-10-lun-60
129: /dev/disk/dsk62c DEC HSG bus-5-targ-10-lun-61
130: /dev/disk/dsk63c DEC HSG bus-5-targ-10-lun-62